Sign In | Join Free | My chinalane.org
China Xi'an Xigao Electricenergy Group Co., Ltd. logo
Xi'an Xigao Electricenergy Group Co., Ltd.
Xi'an Xigao Electricenergy Group Co., Ltd.
Verified Supplier

5 Years

Home > Vacuum Circuit Breaker >

Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System

Xi'an Xigao Electricenergy Group Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System

Brand Name : XG

Model Number : ZN23

Certification : ISO CCC

Place of Origin : XIAN, China

MOQ : 1set

Price : Negitionable

Payment Terms : L/C, T/T, D/A, D/P, Western Union, MoneyGram

Supply Ability : 2000 SET

Delivery Time : 7-15 DAYS

Packaging Details : WOODEN CASE

Name : Outdoor VCB Breaker

Application : Power Distribution System

Warranty : 12 months

OEM : Yes

Voltage : 40.5Kv

Operation type : electric or manual

Contact Now

Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System

1. Outdoor VCB Breaker

ZN23-40.5 Acb Circuit Breaker is 40.5 KV rated voltage, three-phase ac 50 hz indoor high voltage electrical equipment, applicable to substations, industry and mining, urban and rural electric power networks, especially for occasions with frequent operation and automatic power distribution network.


2. Parameter of Outdoor VCB Breaker

NO Item Units Technical parameters
1 Rated voltage kV 40.5
2 Thunder impulse withstand voltage(peak value) kV 185
3 lmin industrial frequency withstand voltage kV 95
4 Rated frequency Hz 50
5 Rated current A 1250,1600,2000
6 Rated short-circuit break current kA 25 31.5
7 Rated peak value withstand current kA 25 31.5
8 Rated peak value withstand current KA 63 80
9 Rated short-circuit duration time s 4
10 Rated short circuit breaking time ms
11 Rated short circuit closing current kA 80
12 Rated operation order 0-0.3s-C0-180s-C0
13 Time of closing brake ms 50~85
14 Time of breaking brake ms 40~85
15 Rated short-circuit current break and close times Times 20
16 Mechanical life-span Times 10000
17 Rated dropout current of condenser bank A 630
18 Rated power of energy-storage electric machine W 275
19 Rated volt of energy-storage motor V 25 ± 2
20 Storage time S ≤15
21 Closing and opening solenoid rated voltage V ≈220,110
22 Loss of pressure tripping device rated voltage V ≈220,110
23 Over current tripping device rated current A 5
24 Auxiliary switch rated voltage current A DC10


3. Working application
Amplitude: earthquake intensity does not exceed 8 °,
Air relative humidity on average less than 95%, on average less than 90%
An ambient air temperature: to +40 °C, the lower limit of -150°C,
Altitude:. ≤ 1000m (For higher altitudes, the rated insulation board level relative increase)
No risk of fire, explosion, serious pollution, chemical corrosion and severe vibration.

4. Technical drawings
Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System

5. Factory
Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System


Product Tags:

40.5Kv Outdoor VCB Breaker

      

Three Phase Outdoor VCB Breaker

      

40.5Kv Power Distribution VCB Breaker

      
Wholesale Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System from china suppliers

Three Phase 40.5Kv Outdoor VCB Breaker Power Distribution System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Xigao Electricenergy Group Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)